Project background
With the continuous development of electronic information technology, Internet of Things, information networking and other technologies, computer rooms with different scales, types of equipment, and numbers are widely distributed in various industries. Due to the lack of corresponding management and monitoring methods, changes in the operating conditions, environmental operating conditions, and firefighting conditions of the UPS power supply in a large number of unattended computer rooms may cause critical situations, and these emergencies cannot If discovered and dealt with in time, it is easy to cause unnecessary losses. Therefore, a complete computer room monitoring system is very important for monitoring the power and environment of the computer room.
The person in charge of the computer room of a company contacted us, hoping to centrally monitor the UPS power supply operation and environmental conditions in the 4 computer rooms, and monitor the real-time temperature, humidity, smoke detection, water leakage and other status in each computer room at any time, as well as the status of each UPS power supply. Voltage, current, temperature, load, input/output voltage, input/output frequency...
User problem:
(1) If the 4 computer rooms are assigned to be on duty, the cost is high, and manual inspections are prone to errors and omissions.
(2) It is impossible to know the operating status and abnormal alarm information of the UPS power supply in each computer room for the first time, and it is impossible to eliminate hidden dangers and faults in time.
(3) When the UPS power supply is abnormal, it is difficult to trace the historical operation records of the UPS power supply and the source of the accident.
(4) It is impossible to know the changes in the environmental temperature and humidity, water leakage, smoke detection and other categories of each computer room in real time. When there is an abnormality, there is no warning prompt.
solution
According to the needs of users and the equipment situation of the computer room, a solution that integrates UPS and the environment of the computer room is selected to effectively realize the centralized monitoring of multiple computer rooms. The user can centrally view and manage the real-time operating status of UPS power supplies in multiple computer rooms, as well as environmental temperature and humidity detection, water leakage (water immersion) detection, fire smoke detection, infrared passive intrusion detection, door sensor (door opening) detection, Status changes of items such as mains input status detection. When monitoring any abnormal situation such as mains power failure, temperature and humidity exceeding upper/lower limits in any computer room, it immediately sends out local sound and light alarms, text messages, phone calls, WeChat, email alarms and other alarm methods to notify multiple management in time member.
Features
1. Support most of the UPS brands such as Golden Samurai, APC, Santak, Costa, etc., and accept the UPS agreement provided by the manufacturer for customization. The UPS power supplies of different brands and models can also be monitored in a unified manner.
2. The UPS environment integrated monitoring host used in a single computer room can support 1 UPS, 6 relay control outputs, 8 temperature and humidity monitoring, and 15 switch inputs.
3. The monitoring host supports multiple versions of SNMP software, has a network interface and an intuitive web page display, to achieve remote monitoring functions. At the same time, it also has an RS485 interface and adopts the popular modbus protocol, which can realize integrated monitoring of non-network computer rooms, forming a synchronous query of monitoring data in a single computer room or multiple computer rooms.
4. There are two ways to view the operating status of UPS and environmental monitoring in each computer room in real time, a centralized monitoring platform (PC terminal) and mobile phone WeChat.
5. The centralized monitoring platform can be integrated into multiple computer rooms for unified management, and at the same time supports area division, which is convenient for users to query the real-time operating status of the UPS and the environment in the specified computer room.
6. Adding equipment to the monitoring platform is simple and fast. Enter the IP address of the device and select the area to be added. At the same time, the device name can be customized to make it easier for users to distinguish the device.
7. A variety of alert notification methods are available for users to choose, and the host has its own email alert and WeChat alert. Optional SMS alarm, telephone voice alarm, local sound and light alarm.
Interface display
1. Centralized monitoring platform interface: Contains operating status, data; historical data, events, alarm status, and regional map interface, etc., allowing users to intuitively read each item of data.
2. Mobile phone WeChat monitoring interface: Contains operating status, data; historical data, events; alarm information interface, etc., through the mobile phone WeChat allows users to intuitively read the real-time operating status of each device.
Plan configuration
The equipment configuration of this program can be flexibly configured according to the user's specific equipment quantity and requirements, and it can also be customized to support the user's specific requirements.